We present a conceptual design for the atmospheric dispersion corrector (ADC) for TMT's Infrared Imaging Spectrograph (IRIS). The severe requirements of this ADC are reviewed, as are limitations to observing caused by uncorrectable atmospheric effects. The requirement of residual dispersion less than 1 milliarcsecond can be met with certain glass combinations. The design decisions are discussed and the performance of the design ADC is described. Alternative options and their performance tradeoffs are also presented.
Bauman Brian J.
Cramptone David
Larkin James E.
Moore Anna M.
Niehaus Cynthia N.
No associations
LandOfFree
The Infrared Imaging Spectrograph (IRIS) for TMT: the atmospheric dispersion corrector does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with The Infrared Imaging Spectrograph (IRIS) for TMT: the atmospheric dispersion corrector, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and The Infrared Imaging Spectrograph (IRIS) for TMT: the atmospheric dispersion corrector will most certainly appreciate the feedback.