Physics – Instrumentation and Detectors
Scientific paper
2006-08-17
AIP Conf.Proc.867:114-121,2006
Physics
Instrumentation and Detectors
8 pages, 7 figures. To appear in the proceedings of CALOR06: 12th International Conference on Calorimetry in High Energy Physi
Scientific paper
10.10to/1.2396945
The electromagnetic barrel calorimeter is one of the main components of the planned GlueX experiment. It will consist of 48 modules made of consecutive layers of 4 m long lead sheet and fast green scintillator fibers for an overall number of approximately 3000 readout channels with silicon photomultiplier-based photo-sensors for light collection. The calorimeter is expected to achieve energy and time resolution better than 5%/sqrt(E)+2% and 200 ps, respectively. In this contribution we present an overview of the calorimeter design and some preliminary studies of its performance using Monte Carlo simulations and beam test measurements.
No associations
LandOfFree
The Electromagentic Barrel Calorimeter for the GlueX Experiment does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with The Electromagentic Barrel Calorimeter for the GlueX Experiment, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and The Electromagentic Barrel Calorimeter for the GlueX Experiment will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-388923