The CDMS II Z-sensitive ionization and phonon germanium detector

Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

11

Scientific paper

The last year saw major progress in the development of the nuclear-recoil dark matter detector for the Cryogenic Dark Matter Search (CDMS II) experiment. The basic γ-ray background discrimination is based on ionization yield. However, as shown in separate experiments, surface events and especially electrons also results in low ionization yield due to incomplete charge collection. The two-fold strategy to reduce these unwanted backgrounds was to improve charge collection at the detector surface and to employ fast phonon sensors on Ge. A 250g Ge detector with an Al Schottky contact on an amorphous Si blocking layer and a Quasiparticle-trap-assisted Electrothermal-feedback Transition-edge (QET) phonon sensor has been characterized. The phonon collection efficiency of the new detector is similar to that of the latest 100g Si Fast Large Ionization and Phonon (FLIP) detector, which has the same phonon sensor design. The fall times of the phonon pulses are longer and consistent with simulations. The charge collection at the surface is high and very similar to that of smaller test devices and the last revision of Berkeley Large Ionization and Phonon (BLIP) detectors. The four fast non-thermal phonon sensors yield x,y position resolution similar to the Si FLIP detector. A rise time surface effect was demonstrated on both sides of the detector. The effect results in a much more effective rejection of surface events than the rejection based on charge yield alone and therefore improves the sensitivity for a dark matter search.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

The CDMS II Z-sensitive ionization and phonon germanium detector does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with The CDMS II Z-sensitive ionization and phonon germanium detector, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and The CDMS II Z-sensitive ionization and phonon germanium detector will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1626625

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.