The angular coverage extension of the KLOE-2 electromagnetic calorimeter, from a polar angle of 20º down to 8º, will increase the multiphoton detection capability of the experiment enhancing the search reach for rare kaon, η and η' prompt decay channels. The basic layout of the calorimeter extension consists of two small barrels of LYSO crystals readout with APD photosensors aiming to achieve a timing resolution between 300 and 500 ps for 20 MeV photons. The first test of a (5.5 × 6 × 13) cm3 prototype for such a detector was carried out at the Beam Test Facility of Laboratori Nazionali di Frascati of INFN and we present here the first results.
Cordelli Marco
Happacher F.
Martini Manuele
Miscetti S.
Sarra I.
No associations
LandOfFree
Test of a LYSO matrix with an electron beam between 100 and 500 MeV for KLOE-2 does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Test of a LYSO matrix with an electron beam between 100 and 500 MeV for KLOE-2, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Test of a LYSO matrix with an electron beam between 100 and 500 MeV for KLOE-2 will most certainly appreciate the feedback.