Physics – Medical Physics
Scientific paper
Apr 2010
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2010apsp.conf...85a&link_type=abstract
ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS. Proceedings of the 11th Conference. Held
Physics
Medical Physics
Rpcs, Rate Capability
Scientific paper
The ATLAS RPCs with 2 mm gas gap were successfully tested at rates as high as 1.0 kHz/cm2. The counting rate capability decreases with the operating current, which is proportional to the charge delivered in the gas at each count of the detector. In this paper preliminary results are presented on the performances of small size RPC prototype, using a newly designed front-end circuit. A relevant improvement was achieved: a good, stable efficiency working point was found with average delivered charge per count almost one order of magnitude smaller than in the ATLAS RPCs.
Aielli G.
Camarri P.
Cardarelli R.
di Ciaccio Anna
di Stante L.
No associations
LandOfFree
Test for upgrading RPCs at very high counting rate does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Test for upgrading RPCs at very high counting rate, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Test for upgrading RPCs at very high counting rate will most certainly appreciate the feedback.