Physics – Instrumentation and Detectors
Scientific paper
2007-03-05
Physics
Instrumentation and Detectors
13 pages, 6 figures
Scientific paper
We consider a far infrared (terahertz), room-temperature detector based on a microcantilever sensor of the radiation pressure. This system has a significantly higher sensitivity than existing uncooled detectors in the far infrared (terahertz) spectral region. The significant enhancement of sensitivity is due the combination non-absorption detection method and high quality optical microcavity. Our theoretical analysis of the detector sensitivity and numerical simulations demonstrate that the narrowband heterodyne detector with the band width 30 MHz has a minimal measurable intensity by three orders of magnitude less than conventional uncooled detectors. In the case of the broadband detector, the noise equivalent temperature difference (NETD) is 7.6 mK, which is significantly smaller than for conventional uncooled thermal detectors.
Berman Gennady P.
Bishop Alan R.
Chernobrod Boris M.
Gorshkov Vyacheslav N.
No associations
LandOfFree
Terahertz and Infrared Uncooled Detector Based on a Microcantilever as a Radiation Pressure Sensor does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Terahertz and Infrared Uncooled Detector Based on a Microcantilever as a Radiation Pressure Sensor, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Terahertz and Infrared Uncooled Detector Based on a Microcantilever as a Radiation Pressure Sensor will most certainly appreciate the feedback.