Physics
Scientific paper
Oct 1994
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=1994jgr....9919597m&link_type=abstract
Journal of Geophysical Research (ISSN 0148-0227), vol. 99, no. A10, p. 19,597-19,607
Physics
1
Bias, Electric Conductors, Electric Current, Electric Potential, Electrostatic Probes, High Voltages, Plasmas (Physics), Wakes, Electric Fields, Extraterrestrial Environments, Ions, Plasma Potentials, Spheres
Scientific paper
The temporal evolution of the voltage-current characteristic of a spherical Langmuir probe in the near-wake region of a conducting body is investigated in a pulsed plasma device. Measurements of the current collected by a sphere placed on axis behind a conducting disk are presented as a function of the bias voltage and time. The bias voltage on the collecting sphere is large enough, ranging from +500 to -3000 V, to attract ions or electrons across the wake region. In addition, plasma potential profiles as a function of sphere bias voltage and time throughout the nearwake and midwake region are presented. It is found that for a negative sphere bias a threshold voltage exists for current collection. This threshold voltage decreases during the formation of the wake behind the conducting disk. Potential measurements indicate that the sheath region around the negatively biased sphere contracts as the wake region establishes itself. This contraction of the sheath region increases the electric field attracting ions to the sphere and decreases the threshold voltage for current collection. For positive sphere bias voltage the current collected by the sphere does not exhibit a threshold voltage but is monotonically increasing.
Chan Cheong
Meassick S.
No associations
LandOfFree
Temporal study of the current collected by a Langmuir probe biased to high voltages in the wake behind a conducting body does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Temporal study of the current collected by a Langmuir probe biased to high voltages in the wake behind a conducting body, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Temporal study of the current collected by a Langmuir probe biased to high voltages in the wake behind a conducting body will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1071916