Spectralon diffuser calibration for MERIS

Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

One of the key payload instruments of ESA's ENVISAT polar platform is the medium resolution imaging spectrometer (MERIS), aiming at improved knowledge of our planet in the fields of bio-optical oceanography, and atmospheric and land surface processes. MERIS, which is built under responsibility of Aerospatiale, will monitor the solar irradiation scattered by the Earth by employing five cameras which simultaneously record data in 15 visible and near-infrared programmable spectral bands with very low degree of polarization sensitivity. The combined field-of-view of the five cameras spans a range of 68.5 degrees. Crucial for obtaining the desired high accuracy during a four-years lifetime, is the on- board calibration unit. This calibration unit contains a set of Spectralon diffusers, which were manufactured having in mind excellent in-flight stability as well as spectral and spatial uniformity. Preflight calibration of the Spectralon diffusers was carried out at TNO-TPD. This calibration includes the measurement of the bidirectional reflectance distribution function (BRDF) for applicable angles and wavelengths, i.e., while varying angle of incidence, angle of observation, observation area on the elongated diffusers, wavelength and polarization. The diffuser calibration was performed in a class 100 cleanroom. For these measurements the TPD calibration facility, which is described in detail, has been adapted, so that it now has five geometrical degrees of freedom. Detectors have been optimized to minimize stray light. Due to extensive commissioning of the calibration setup the absolute error (1 sigma) of these measurements amounts to less than 0.5%; relative errors are in the 0.3 - 0.4% range.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Spectralon diffuser calibration for MERIS does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Spectralon diffuser calibration for MERIS, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Spectralon diffuser calibration for MERIS will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1045490

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.