Source of soft x-rays with an x-ray optical system for submicron lithography

Physics – Optics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

A system for X-ray lithography has been developed at the Institute for X-Ray Optical Systems (Moscow) which utilizes a powerful plasma pulse source of VUV and soft rays together with an X-ray optical system (XOS) of the Kumakhov lens type. The XOS provides the opportunity to control the distribution and divergence of the X-ray emission. The source of X-rays is a micropinch narrowing of a plasma pulse electric discharge of the low-inductive 'vacuum spark' type in the vapors of the electrode material. Typical parameters of the source are: energy stored in the capacitors, 500 Joules; emitted energy of X-rays in a band near 1 Kev, 8 - 10 J (efficiency to 2%); energy of VUV emission (20 - 1000 A), about 50 J; emission pulse time, 10 ns, frequency of discharges up to 15 Hz. The dimensions of the micropinch spot is 50 - 100 micrometers but the position of the pulse varies up to 3 mm. The capillary optic system contains about 3000 glass capillaries with variable cross-section and is 600 mm in length. The diameter of the output cross-section of the 'semilens' is 60 mm which provides uniform illumination of a 40 X 40 mm(superscript 2) mask. The distance between the source and the XOS input is 100 mm. The density of X-rays at the XOS input is 200 mW/cm(superscript 2). With a 50% transmission efficiency and a relative input-to-output cross-section of 0.2, the density of X-ray emission on the wafer is expected to be about 10 mW/cm(superscript 2). Using a negative resist with a sensitivity of 20 mJ/cm(superscript 2), this leads to an exposure time of about 2 seconds per field. With the use of a capillary lens, the angular divergence is not controlled by the c position jitter but by the lens and is about 3 milliradians. The current status of this system will be described.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Source of soft x-rays with an x-ray optical system for submicron lithography does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Source of soft x-rays with an x-ray optical system for submicron lithography, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Source of soft x-rays with an x-ray optical system for submicron lithography will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1265858

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.