Physics
Scientific paper
Aug 2001
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2001icrc....6.2309f&link_type=abstract
Proceedings of the 27th International Cosmic Ray Conference. 07-15 August, 2001. Hamburg, Germany. Under the auspices of the Int
Physics
Scientific paper
The project small-sized, small weight and lowpowered of a satellite telescope-spectrometer of charged particles is offered. The device consists of two silicon detectors, arranged sequentially concerning a particle flux, and then scintillation detector. The silicon detectors have depth within the limits of 150-300 microns and fissile area 5 m2 . The scintillation detector consists of a chip CsJ(Tl) and photoconverter, which role executes the same silicon detector. The measurement Δ<1Δ<2< allows to identify signals from different particles: electrons, protons and more massive ions. The essential difficulty is connected to necessity of simultaneous fulfilment for silicon detectors of two conflicting objective: the large active area and high responses on a charge suffices which should provide reliable registration of high energy electrons. The escaping of this inconsistency is retrieved in division of the detector into separate sections, the signals from which strengthen in different channels and then special mode are admixed. It allows in N of time (N number of sections) to reduce an electrical detector noise and channel of amplification. Therefore silicon detectors are made as matrix 2x2 units. If necessary to determine angular distributions of particles silicon detectors place on definite distance from each other, that allows to conduct measurements in 16 solid angles. Experimental outcomes on the obtained matrixes: an electrical noise of each matrixes units is 11 keV, energy resolution on α-particles 241 Am 23 keV. The frequency of spurious noise impulses with energy is higher 15 keV makes less than 1 for 5 minutes. Such characteristics allow confidently to abjoint signals of mip-particles from electric noises. The channels of processing of signals of silicon detectors have the following characteristics: initial intake noise is 7 keV, declination of a noise performance 15 eV/pF at time of formation τ=3 μS. A volume range not less than 55 dB. Correspond to: Shevchenko Valeriy, shevfis@carrier.kiev.ua The computational volume of detectors and analogue part of an electronics engineering of a telescope spectrometer makes no more 0,5 litre, weight less 0,5 kg and consumed power about 1 W.
Frolov D. O.
Frolov O. S.
Sadovnichiy A. A.
Shevchenko V. A.
Zaitchevskiy I. L.
No associations
LandOfFree
Small-sized and low-powered of a satellite telescope-spectrometer of charged particles does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Small-sized and low-powered of a satellite telescope-spectrometer of charged particles, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Small-sized and low-powered of a satellite telescope-spectrometer of charged particles will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-794635