Physics
Scientific paper
Dec 1988
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=1988nimpa.273..257t&link_type=abstract
Nuclear Instruments and Methods in Physics Research Section A, Volume 273, Issue 1, p. 257-261.
Physics
1
Scientific paper
The response function of a beta detector telescope consisting of a 15 mm thick high purity germanium detector stacked with a 1 mm thick plastic scintillation detector has been determined. The telescope covers the energy range from 1 to 14 MeV. Detector response and relative efficiencies were measured at four electron energies between 2.5 and 8.5 MeV. The monoenergetic electrons were obtained using conversion electrons originating from thermal neutron capture in a 113Cd target.
Tengblad Olof
von Dincklage Ralph
No associations
LandOfFree
Response function of a beta detector telescope consisting of HPGe and scintillator does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Response function of a beta detector telescope consisting of HPGe and scintillator, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Response function of a beta detector telescope consisting of HPGe and scintillator will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1759353