Rapid Simultaneous Mapping of Total and Myelin Water Content, T1 and T2* in Multiple Sclerosis

Physics – Medical Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

27 pages, 4 figures

Scientific paper

Quantitative magnetic resonance imaging might provide a more specific insight into disease process, progression and therapeutic response of multiple sclerosis. We present an extension of a previously published approach for the simultaneous mapping of brain T1, T2* and total water content. In addition to those three parameters, the method presented in the current work allows for the measurement of myelin bound water content, a surrogate marker of tissue myelination. Myelin water was measured based on its distinct relaxation with reduced T2*, resulting in a multiexponential decay signal. However, only 10 points could be acquired on the relaxation curve within a maximum echo time of <40ms as the quantitative protocol has been adapted previously for fast acquisitions with whole brain coverage. The sparse sampling required an adaption of the optimisation approach with additional constraints necessary in order to obtain reliable results. Therefore, the corresponding pool fractions were determined using linear optimisation instead of the standard nonnegative least squares (NNLS). The whole approach including the proper choice of constraints was optimised and validated in simulation studies. Furthermore, the independent determination of total water content allows for an absolute quantification of myelin water content, resulting in a more reliable measurement in oedemateous tissue. Whole brain maps of T1, T2*, total and myelin water content were acquired in 12 patients suffering from multiple sclerosis with mild disease grade. With an acquisition time of 10 minutes only, the presented multidimensional quantitative MRI protocol provides an interesting option for the clinical assessment and monitoring of multiple sclerosis, even on a routine basis.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Rapid Simultaneous Mapping of Total and Myelin Water Content, T1 and T2* in Multiple Sclerosis does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Rapid Simultaneous Mapping of Total and Myelin Water Content, T1 and T2* in Multiple Sclerosis, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Rapid Simultaneous Mapping of Total and Myelin Water Content, T1 and T2* in Multiple Sclerosis will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-400705

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.