The MuCool Test Area (MTA) is an intense primary beam facility derived directly from the Fermilab Linac to test heat deposition and other technical concerns associated with the liquid hydrogen targets being developed for cooling intense muon beams. In this shielding study the results of Monte Carlo radiation shielding calculations performed using the MARS14 code for the MuCool Test Area and including the downstream portion of the target hall and berm around it, access pit, service building, and parking lot are presented and discussed within the context of the proposed MTA experimental configuration.
Johnstone Callum
Rakhno Igor
No associations
LandOfFree
Radiation shielding calculations for MuCool Test Area at Fermilab does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Radiation shielding calculations for MuCool Test Area at Fermilab, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Radiation shielding calculations for MuCool Test Area at Fermilab will most certainly appreciate the feedback.