Pulsar huge array with Nyquist-rate digital lens and prism

Computer Science

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

13

Scientific paper

An 8 X 8 equals 64 element digital interferometer was developed at Waseda University (1989 - 1995). It was an equally spaced two dimensional array of 2.4 m dishes at 10.6 GHz, and a 2D FFT processor was used for Nyquist rate imaging. Recently a spatial-temporal (2 + 1)D FFT processor has been developed for pulsar survey (1996 - 2000), in which a first 2D spatial FFT transforms the electric fields of coordinate represented to those of momentum represented. We obtain the electric fields in each 64 direction at Nyquist rate by the 2D spatial Fourier transform. The following temporal 1D FFT gives the spectrum of 64ch or 256ch to 64 directions respectively also at Nyquist rate. The total bandwidths of each direction are 20 MHz and the resulting frequency resolutions are 20/64 MHz or 20/256 MHz. For sensitive pulsar survey, we also have developed an interferometric array of 20 m spherical dishes in Nasu flat, 160 km north of Tokyo. Five dishes are completed at present. Normal temperature receivers of high electron mobility transistors (HEMT) are used at 1.4 GHz observation and the receiver noise temperatures are below 40 K. Expected rms detection limit (Delta) T is about 10-2K under the condition of 20 MHz band widths and 1s integration time. Preliminary results of zenith survey at (delta) equals 40 deg using a single dish show (Delta) T equals 0.03 K without switching. Sub-reflectors and feed horns were designed so as to observe 5 deg off directions from zenith and they rotate around Az axis. It enable us to survey the declination zone of 32

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Pulsar huge array with Nyquist-rate digital lens and prism does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Pulsar huge array with Nyquist-rate digital lens and prism, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Pulsar huge array with Nyquist-rate digital lens and prism will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1482553

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.