Physics – Quantum Physics
Scientific paper
2009-07-13
Physics
Quantum Physics
accepted for publication in App. Phys. Lett
Scientific paper
We present a theoretical calculation of the pull-in control in capacitive micro switches actuated by Casimir forces, using external magnetic fields. The external magnetic fields induces an optical anisotropy due to the excitation of magneto plasmons, that reduces the Casimir force. The calculations are performed in the Voigt configuration, and the results show that as the magnetic field increases the system becomes more stable. The detachment length for a cantilever is also calculated for a cantilever, showing that it increases with increasing magnetic field. At the pull-in separation, the stiffness of the system decreases with increasing magnetic field.
Cocoletzi G. H.
Esquivel-Sirvent Raul
Palomino-Ovando M. A.
No associations
LandOfFree
Pull-in control due to Casimir forces using external magnetic fields does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Pull-in control due to Casimir forces using external magnetic fields, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Pull-in control due to Casimir forces using external magnetic fields will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-331316