Proton Irradiation Experiment for the X-ray Charge-Coupled Devices of the Monitor of All-sky X-ray Image mission onboard the International Space Station: I. Experimental Setup and Measurement of the Charge Transfer Inefficiency

Physics – Instrumentation and Detectors

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

17 pages, 2 table, 12 figures. Accepted for publication of Japanese Journal of Applied Physics. High resolution file is availa

Scientific paper

10.1143/JJAP.41.7542

We have investigated the radiation damage effects on a CCD to be employed in the Japanese X-ray astronomy mission including the Monitor of All-sky X-ray Image (MAXI) onboard the International Space Station (ISS). Since low energy protons release their energy mainly at the charge transfer channel, resulting a decrease of the charge transfer efficiency, we thus focused on the low energy protons in our experiments. A 171 keV to 3.91 MeV proton beam was irradiated to a given device. We measured the degradation of the charge transfer inefficiency (CTI) as a function of incremental fluence. A 292 keV proton beam degraded the CTI most seriously. Taking into account the proton energy dependence of the CTI, we confirmed that the transfer channel has the lowest radiation tolerance. We have also developed the different device architectures to reduce the radiation damage in orbit. Among them, the ``notch'' CCD, in which the buried channel implant concentration is increased, resulting in a deeper potential well than outside, has three times higher radiation tolerance than that of the normal CCD. We then estimated the charge transfer inefficiency of the CCD in the orbit of ISS, considering the proton energy spectrum. The CTI value is estimated to be 1.1e-5 per each transfer after two years of mission life in the worse case analysis if the highest radiation-tolerant device is employed. This value is well within the acceptable limit and we have confirmed the high radiation-tolerance of CCDs for the MAXI mission.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Proton Irradiation Experiment for the X-ray Charge-Coupled Devices of the Monitor of All-sky X-ray Image mission onboard the International Space Station: I. Experimental Setup and Measurement of the Charge Transfer Inefficiency does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Proton Irradiation Experiment for the X-ray Charge-Coupled Devices of the Monitor of All-sky X-ray Image mission onboard the International Space Station: I. Experimental Setup and Measurement of the Charge Transfer Inefficiency, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Proton Irradiation Experiment for the X-ray Charge-Coupled Devices of the Monitor of All-sky X-ray Image mission onboard the International Space Station: I. Experimental Setup and Measurement of the Charge Transfer Inefficiency will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-644643

  Search