Precise validation of neutron cross section data bases using a lead slowing down spectrometer and simulation from 0.1 eV to 40 keV. Methodology and data on thin and thick targets and data bases adjustement

Physics – Nuclear Physics – Nuclear Experiment

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

0 pages, 6 tables, to submit in NIM-A

Scientific paper

Research on accelerator driven systems (ADS), related new fuels and their ability for nuclear waste incineration has led to a revival of interest in nuclear cross sections of many nuclides over a large energy range. Discrepancies observed between nuclear data bases require new measurements in several cases. A complete measurement of such cross sections including resonance resolution consists of an extensive beam time experiment associated to a long process of analysis ans validation. With a slowing down spectrometer associated to a pulsed neutron source, it is possible to determine good cross section profile in an energy range from 0.1 eV to 40 keV. These measurements performed at ISN (Grenoble) with neutron source GENEPI requires only small quantities of matter (as small as 0.1 g) and about one day of beam per target.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Precise validation of neutron cross section data bases using a lead slowing down spectrometer and simulation from 0.1 eV to 40 keV. Methodology and data on thin and thick targets and data bases adjustement does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Precise validation of neutron cross section data bases using a lead slowing down spectrometer and simulation from 0.1 eV to 40 keV. Methodology and data on thin and thick targets and data bases adjustement, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Precise validation of neutron cross section data bases using a lead slowing down spectrometer and simulation from 0.1 eV to 40 keV. Methodology and data on thin and thick targets and data bases adjustement will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-124323

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.