We present measurements of position and angular resolution of drift chambers operated with a Xe,CO$_2$(15%) mixture. The results are compared to Monte Carlo simulations and important systematic effects, in particular the dispersive nature of the absorption of transition radiation and non-linearities, are discussed. The measurements were carried out with prototype drift chambers of the ALICE Transition Radiation Detector, but our findings can be generalized to other drift chambers with similar geometry, where the electron drift is perpendicular to the wire planes.
Adler Christopher
TRD collaboration for the ALICE
No associations
LandOfFree
Position Reconstruction in Drift Chambers operated with Xe, CO2 (15%) does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Position Reconstruction in Drift Chambers operated with Xe, CO2 (15%), we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Position Reconstruction in Drift Chambers operated with Xe, CO2 (15%) will most certainly appreciate the feedback.