Portable digital lidar: a compact stand-off bioagent aerosol sensor

Mathematics – Logic

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

Remote detection of biological warfare agents (BWA) is crucial for providing early warning to ensure maximum survivability of personnel in the battlefield and other sensitive areas. Although the current generation of stand- off aerosol and fluorescence lidars have demonstrated stand- off detection and identification of BWA, their large size and cost make them difficult for field use. We have introduced a new eye-safe portable digital lidar (PDL) technique based on digital detection that achieves orders of magnitude reduction in the size, cost and complexity over the conventional lidar, while providing an equal or better sensitivity and range. Excellent performance has been obtained with two of our PDL sensors during two bio-aerosol measurement campaigns carried out at Dugway Proving Grounds. In the JFT 4.5 (Oct 98) tests, high aerosol sensitivity of 300 ppl of biosimulant particles at up to 3 km was demonstrated with an eye-safe wavelength (523nm) aerosol micro PDL that utilized a 8 inch telescope, <10(mu) J/pulse energy at 2.5kHz, photon counting digital detection and 2 sec averaging. For the JBREWS DFT (June 99) tests an eye-safe two wavelengths (523nm and 1.047mum) horizontally scanned, aerosol micro PDL with the same 8 inch telescope was utilized. With this lidar, high sensitivity, preliminary differentiation between natural and unusual clouds, and the ability to track the aerosol cloud location, their wind speed and direction were also demonstrated. Lidar simulations of both PDL and conventional analog detection have been performed. Based on these model calculations and experimental results an analysis and comparison of the inherent capabilities of two types of systems is given.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Portable digital lidar: a compact stand-off bioagent aerosol sensor does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Portable digital lidar: a compact stand-off bioagent aerosol sensor, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Portable digital lidar: a compact stand-off bioagent aerosol sensor will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-820220

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.