Plasma effect is observed in CCDs exposed to heavy ionizing alpha-particles with energies in the range 0.5 - 5.5 MeV. The results obtained for the size of the charge clusters reconstructed on the CCD pixels agrees with previous measurements in the high energy region (>3.5 MeV). The measurements were extended to lower energies using alpha-particles produced by (n,alpha) reactions of neutrons in a Boron-10 target. The effective linear charge density for the plasma column is measured as a function of energy. The results demonstrate the potential for high position resolution in the reconstruction of alpha particles, which opens an interesting possibility for using these detectors in neutron imaging applications.
Blostein J. J.
Estrada J. J.
Fernandez Germán
Molina Jorge
No associations
LandOfFree
Plasma effect in Silicon Charge Coupled Devices (CCDs) does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Plasma effect in Silicon Charge Coupled Devices (CCDs), we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Plasma effect in Silicon Charge Coupled Devices (CCDs) will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-727532