Planck pre-launch status: High Frequency Instrument polarization calibration

Astronomy and Astrophysics – Astrophysics – Cosmology and Extragalactic Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

accepted by Astronomy&Astrophysics

Scientific paper

The High Frequency Instrument of Planck will map the entire sky in the millimeter and sub-millimeter domain from 100 to 857 GHz with unprecedented sensitivity to polarization ($\Delta P/T_{\tiny cmb} \sim 4\cdot 10^{-6}$) at 100, 143, 217 and 353 GHz. It will lead to major improvements in our understanding of the Cosmic Microwave Background anisotropies and polarized foreground signals. Planck will make high resolution measurements of the $E$-mode spectrum (up to $\ell \sim 1500$) and will also play a prominent role in the search for the faint imprint of primordial gravitational waves on the CMB polarization. This paper addresses the effects of calibration of both temperature (gain) and polarization (polarization efficiency and detector orientation) on polarization measurements. The specific requirements on the polarization parameters of the instrument are set and we report on their pre-flight measurement on HFI bolometers. We present a semi-analytical method that exactly accounts for the scanning strategy of the instrument as well as the combination of different detectors. We use this method to propagate errors through to the CMB angular power spectra in the particular case of Planck-HFI, and to derive constraints on polarization parameters. We show that in order to limit the systematic error to 10% of the cosmic variance of the $E$-mode power spectrum, uncertainties in gain, polarization efficiency and detector orientation must be below 0.15%, 0.3% and 1\deg\ respectively. Pre-launch ground measurements reported in this paper already fulfill these requirements.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Planck pre-launch status: High Frequency Instrument polarization calibration does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Planck pre-launch status: High Frequency Instrument polarization calibration, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Planck pre-launch status: High Frequency Instrument polarization calibration will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-379852

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.