Hamamatsu R5900-00-M64 and R7600-00-M64 photomultiplier tubes will be used
with wavelength--shifting optical fibres to read out scintillator strips in the
MINOS near detector. We report on measurements of the gain, efficiency,
linearity, crosstalk, and dark noise of 232 of these PMTs, of which 219 met
MINOS requirements.
Barker M. A.
Cabrera Alejandro
de Santo A.
Lang Karol
Michael D.
No associations
LandOfFree
Performance of Hamamatsu 64-anode photomultipliers for use with wavelength--shifting optical fibres does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Performance of Hamamatsu 64-anode photomultipliers for use with wavelength--shifting optical fibres, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Performance of Hamamatsu 64-anode photomultipliers for use with wavelength--shifting optical fibres will most certainly appreciate the feedback.