We report on test results of a novel ring imaging Cherenkov (RICH) detection
system consisting of a 3 meter long gaseous C4F8O radiator, a focusing mirror,
and a photon detector array based on Hamamatsu multi-anode photomultiplier
tubes. This system was developed to identify charged particles in the momentum
range from 3-70 GeV/c for the BTeV experiment.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Performance of a C4F8O Gas Radiator Ring Imaging Cherenkov Detector Using Multi-anode Photomultiplier Tubes does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Performance of a C4F8O Gas Radiator Ring Imaging Cherenkov Detector Using Multi-anode Photomultiplier Tubes, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Performance of a C4F8O Gas Radiator Ring Imaging Cherenkov Detector Using Multi-anode Photomultiplier Tubes will most certainly appreciate the feedback.