The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented.
No associations
LandOfFree
Performance and Operation of the CMS Electromagnetic Calorimeter does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Performance and Operation of the CMS Electromagnetic Calorimeter, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Performance and Operation of the CMS Electromagnetic Calorimeter will most certainly appreciate the feedback.