Critically coupled resonant optical cavities are often used as mode cleaners in optical systems to improve the signal to noise ratio (SNR) of a signal that is encoded as an amplitude modulation of a laser beam. Achieving the best SNR requires maintaining the alignment of the mode cleaner relative to the laser beam on which the signal is encoded. An automatic alignment system which is primarily sensitive to the carrier field component of the beam will not, in general, provide optimal SNR. We present an approach that modifies traditional dither alignment sensing by applying a large amplitude modulation on the signal field, thereby producing error signals that are sensitive to the signal sideband field alignment. When used in conjunction with alignment actuators, this approach can improve the detected SNR; we demonstrate a factor of 3 improvement in the SNR of a kilometer-scale detector of the Laser Interferometer Gravitational-wave Observatory. This approach can be generalized to other types of alignment sensors.
Ballmer Stefan
Evans Matt
Frolov Valery
Kawabe Keita
Mavalvala Nergis
No associations
LandOfFree
Optimal Alignment Sensing of a Readout Mode Cleaner Cavity does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Optimal Alignment Sensing of a Readout Mode Cleaner Cavity, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Optimal Alignment Sensing of a Readout Mode Cleaner Cavity will most certainly appreciate the feedback.