The Silicon Pixel Detector (SPD) constitutes the two innermost layers of the Inner Tracking System of the ALICE experiment and it is the closest detector to the interaction point. The SPD has nearly 9.8 × 106 channels and it will operate in a region where the track density could be as high as 50 tracks/cm2. A special effort was made in the designing and construction to reduce the material budget to about 1% X0 per layer. The SPD will also provide a trigger signal within 800 ns latency which will contribute to the L0 trigger definition. In this contribution the SPD running experiences will be presented as well as the readiness of the detector to record the first collisions in LHC.
No associations
LandOfFree
Operation Experience with the ALICE Silicon Pixel Detector with Cosmics and First Beams does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Operation Experience with the ALICE Silicon Pixel Detector with Cosmics and First Beams, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Operation Experience with the ALICE Silicon Pixel Detector with Cosmics and First Beams will most certainly appreciate the feedback.