Scientific paper
An x-ray free electron laser oscillator (XFELO) has been recently proposed [K. Kim, Y. Shvyd'ko, and S. Reiche, Phys. Rev. Lett. 100, 244802 (2008)]. Angular orientation and position in space of Bragg mirrors of the XFELO optical cavity must be continuously adjusted to compensate instabilities and maximize the output intensity. An angular stability of about 10 nrad (rms) is required [K. Kim and Y. Shvyd'ko Phys. Rev. STAB 12, 030703 (2009)]. To approach this goal, a feedback loop based on a null-detection principle was designed and used for stabilization of a high energy resolution x-ray monochromator ($\Delta E/E \simeq 4 \times 10^{-8}$, $E$ = 23.7 keV) and a high heat load monochromator. Angular stability of about 13 nrad (rms) has been demonstrated for x-ray optical elements of the monochromators.
Goetze Kurt
Kim Kwang-Je
Laird Robert
Lenkszus Frank
Shvyd'ko Yuri
No associations
LandOfFree
Nanoradian angular stabilization of x-ray optical components does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Nanoradian angular stabilization of x-ray optical components, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Nanoradian angular stabilization of x-ray optical components will most certainly appreciate the feedback.