MUST: A silicon strip detector array for radioactive beam experiments

Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

33

Scientific paper

A new and innovative array, MUST, based on silicon strip technology and dedicated to the study of reactions induced by radioactive beams on light particles is described. The detector consists of 8 silicon strip - Si(Li) telescopes used to identify recoiling light charged particles through time of flight, energy loss and energy measurements and to determine precisely their scattering angle through X,Y position measurements. Each /60×60mm2 double sided silicon strip detector with 60 vertical and 60 horizontal strips yields an /X-/Y position resolution of 1mm, an energy resolution of 50keV, a time resolution of around 1ns and a 500keV energy threshold for protons. The backing Si(Li) detectors stop protons up to 25MeV with a resolution of approximately 50keV. CsI crystals read out by photo-diodes which stop protons up to 70MeV are added to the telescopes for applications where higher energy particles need to be detected. The dedicated electronics in VXIbus standard allow us to house the 968 logic and analog channels of the array in one crate placed adjacent to the reaction chamber and fully remote controlled, including pulse visualization on oscilloscopes. A stand alone data acquisition system devoted to the MUST array has been developed. Isotope identification of light charged particles over the full energy range has been achieved, and the capability of the system to measure angular distributions of states populated in inverse kinematics reactions has been demonstrated.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

MUST: A silicon strip detector array for radioactive beam experiments does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with MUST: A silicon strip detector array for radioactive beam experiments, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and MUST: A silicon strip detector array for radioactive beam experiments will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-946937

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.