A thermal sensor measurement system, with a resolution better than 0.01 C has been built for the NOAO 3.5-m mirror project. A total of 1000 low-cost precision temperature current transducers are multiplexed through a single 16-bit ADC so that temperature profiles may be obtained in less than 30 sec. The problems and pitfalls encountered in taking a device that was designed to be accurate to 0.5 C and obtaining reliable measurements to + or - 0.003 C with a large number of sensors are discussed.
Dryden David M.
Pearson Earl T.
No associations
LandOfFree
Multiplexed precision thermal measurement system for large structured mirrors does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Multiplexed precision thermal measurement system for large structured mirrors, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Multiplexed precision thermal measurement system for large structured mirrors will most certainly appreciate the feedback.