Multi-element, large-volume CdZnTe detectors

Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

3

Scientific paper

Many applications using gamma rays, such as the determination of the elemental composition of planetary bodies, require the detection of gamma rays in the energy range 100keV-10MeV in a light, compact, room-temperature system. The photopeak efficiency of a single CdZnTe detector is limited because the volume currently available is limited to about 3.4cm3. To achieve adequate efficiency, we have combined the signals from several large-volume, coplanar-grid CdZnTe detectors. At low energy, the signals are summed without requiring coincidence; at high energy, multi-fold coincidence is required to suppress the Compton continuum. To minimize noise, a signal from a single detector is only included in the sum if it exceeds a threshold set just above the noise. We describe the electronics, the single detectors, their packaging in thin-walled boxes, and the resulting spectra. The energy resolution for the combined spectrum is only slightly worse than the resolution of the single detectors. The effectiveness of the Compton suppression depends on the spectrum. The photopeak efficiency of the multi-element detector when the signals are summed without requiring coincidence is approximately the sum of the photopeak efficiencies of the single detectors, whereas the photopeak efficiency with Compton suppression is a more complicated function of the incident gamma-ray energy. These results indicate that a 27-element (3×3×3) array of 15mm×15mm×15mm single detector elements can provide good gamma-ray data for planetary bodies and terrestrial applications requiring high-efficiency, good-resolution portable instruments.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Multi-element, large-volume CdZnTe detectors does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Multi-element, large-volume CdZnTe detectors, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Multi-element, large-volume CdZnTe detectors will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1215523

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.