Modelling of magnetic field structure of the Ergodic Divertor of Tore Supra and comparison to the Dynamic Ergodic Divertor of TEXTOR

Physics – Plasma Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

32 pages, 27 figures

Scientific paper

An analytical model previously developed to study the structure of the magnetic field for the TEXTOR-DED [S.S. Abdullaev et al. Phys. Plasmas, 6, 153 (1999)] is applied to the similar study of the Ergodic Divertor of Tore Supra tokamak [Ph. Ghendrih, Plasma Phys. Control. Fusion, 38, 1653 (1996)]. The coil configuration of ED Tore Supra consists of six modules equidistantly located along the toroidal direction on the low-field-side of the torus with given toroidal and poloidal extensions. The Hamiltonian formulation of field line equations in straight-field-line coordinates (Boozer coordinates) and the computationally efficient mapping method for integration of the Hamiltonian field line equations are used to study the magnetic field structure in the ED. Asymptotical formulas for the perturbation magnetic field created by the ED coils are obtained and the spectrum of magnetic perturbations is analyzed and compared with the one of the TEXTOR-DED. The structure of ergodic and laminar zones are studied by plotting Poincare sections, so-called laminar plots (contour plots of wall to wall connection lengths) and magnetic footprints. The radial profiles of field line diffusion coefficients are calculated for different perturbation currents and it is found that for the Tore Supra case in the ergodic zone the numerical field line diffusion coefficients perfectly follow the quasilinear formula for smaller perturbation currents although the situation is different for the maximum perturbation current.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Modelling of magnetic field structure of the Ergodic Divertor of Tore Supra and comparison to the Dynamic Ergodic Divertor of TEXTOR does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Modelling of magnetic field structure of the Ergodic Divertor of Tore Supra and comparison to the Dynamic Ergodic Divertor of TEXTOR, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Modelling of magnetic field structure of the Ergodic Divertor of Tore Supra and comparison to the Dynamic Ergodic Divertor of TEXTOR will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-188771

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.