Physics – High Energy Physics – High Energy Physics - Experiment
Scientific paper
2003-01-10
Nucl.Instrum.Meth.A500:441-445,2003
Physics
High Energy Physics
High Energy Physics - Experiment
8 pages, 2 figures
Scientific paper
10.1016/S0168-9002(03)00339-5
The experimental problem of the calibration of magnetic field in large iron detectors is discussed. Emphasis is laid on techniques based on ballistic measurements as the ones employed by MINOS or OPERA.In particular, we provide analytical formulas to model the behavior of the apparatus in the transient regime, keeping into account eddy current effects and the finite penetration velocity of the driving fields. These formulas ease substantially the design of the calibration apparatus.Results are compared with experimental data coming from a prototype of the OPERA spectrometer.
Incurvati M.
Terranova Francesco
No associations
LandOfFree
Modeling skin effect in large magnetized iron detectors does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Modeling skin effect in large magnetized iron detectors, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Modeling skin effect in large magnetized iron detectors will most certainly appreciate the feedback.