The International Linear Collider (ILC) Time Projection Chamber (TPC) transverse space-point resolution goal is 100 microns for all tracks including stiff 90 degree tracks with the full 2 meter drift. A Micro Pattern Gas Detector (MPGD) readout TPC can achieve the target resolution with existing techniques using 1 mm or narrower pads at the expense of increased detector cost and complexity. The new MPGD readout technique of charge dispersion can achieve good resolution without resorting to narrow pads. This has been demonstrated previously for 2 mm x 6 mm pads with GEMs and Micromegas in cosmic ray tests and in a KEK beam test in a 1 Tesla magnet. We have recently tested a Micromegas-TPC using the charge dispersion readout concept in a high field super-conducting magnet at DESY. The measured Micromegas gain was found to be constant within 0.5% for magnetic fields up to 5 Tesla. With the strong suppression of transverse diffusion at high magnetic fields, we measure a flat 50 micron resolution at 5 Tesla over the full 15 cm drift length of our prototype TPC.
Attie David
Bellerive Alain
Boudjemline K.
Colas Paul
Dixit Authors M.
No associations
LandOfFree
Micromegas TPC studies at high magnetic fields using the charge dispersion signal does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Micromegas TPC studies at high magnetic fields using the charge dispersion signal, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Micromegas TPC studies at high magnetic fields using the charge dispersion signal will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-272931