The EUV grating spectrograph (EGS) as part of the Thermosphere-Ionosphere-Mesosphere Energetics and Dynamics (TIMED) solar EUV experiment (SEE) presents a number of performance challenges for its microchannel plate (MCP)- based detector. The EGS measures the solar spectral irradiance from 25 to 200 nm. The intensities of the line and continuum emissions over this spectral range vary by up to five orders of magnitude. While a variety of transmission filters are strategically used to bring the signal over the entire spectrum into the dynamic range of a single chevron pair of MCPs, a number of concerns regarding the characteristic behavior of MCPs remain. The nominal TIMED mission is two years while the extended mission potentially doubles to four years. Over this period, the MCP response is expected to change to some extent. Detailed changes in MCP performance are notoriously application dependent,however. In order to better anticipate and accommodate these changes over the duration of the mission as well as to potentially enhance detector performance, we are performing a series of life-tests on a variety of MCPs. In these tests we characterize MCP gain, pulse height distribution, quantum detection efficiency, and linearity as function of accumulated charge and exposure to atmosphere. Here we report on the result of these test.s

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Microchannel plate performance and life-test results for the TIMED Solar EUV experiment does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Microchannel plate performance and life-test results for the TIMED Solar EUV experiment, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Microchannel plate performance and life-test results for the TIMED Solar EUV experiment will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-805688

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.