Metrological characterization of the pulsed Rb clock with optical detection

Physics – Atomic Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

We report on the implementation and the metrological characterization of a vapor-cell Rb frequency standard working in pulsed regime. The three main parts that compose the clock, physics package, optics and electronics, are described in detail in the paper. The prototype is designed and optimized to detect the clock transition in the optical domain. Specifically, the reference atomic transition, excited with a Ramsey scheme, is detected by observing the interference pattern on a laser absorption signal. \ The metrological analysis includes the observation and characterization of the clock signal and the measurement of frequency stability and drift. In terms of Allan deviation, the measured frequency stability results as low as $1.7\times 10^{-13} \ \tau^{-1/2}$, $\tau$ being the averaging time, and reaches the value of few units of $10^{-15}$ for $\tau=10^{4}$ s, an unprecedent achievement for a vapor cell clock. We discuss in the paper the physical effects leading to this result with particular care to laser and microwave noises transferred to the clock signal. The frequency drift, probably related to the temperature, stays below $10^{-14}$ per day, and no evidence of flicker floor is observed. \ We also mention some possible improvements that in principle would lead to a clock stability below the $10^{-13}$ level at 1 s and to a drift of few units of $10^{-15}$ per day.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Metrological characterization of the pulsed Rb clock with optical detection does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Metrological characterization of the pulsed Rb clock with optical detection, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Metrological characterization of the pulsed Rb clock with optical detection will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-708557

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.