Measurement of the parity violating 6S-7S transition amplitude in cesium achieved within 2 \times 10^{-13} atomic-unit accuracy by stimulated-emission detection

Physics – Atomic Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Article 21 pages, 6 figures, 3 tables Typos, addition of few comments and little more data (1 week) leading to a slight reduct

Scientific paper

10.1103/PhysRevA.71.042108

We exploit the process of asymmetry amplification by stimulated emission which provides an original method for parity violation (PV) measurements in a highly forbidden atomic transition. The method involves measurements of a chiral, transient, optical gain of a cesium vapor on the 7S-6P_{3/2} transition, probed after it is excited by an intense, linearly polarized, collinear laser, tuned to resonance for one hyperfine line of the forbidden 6S-7S transition in a longitudinal electric field. We report here a 3.5 fold increase, of the one-second-measurement sensitivity, and subsequent reduction by a factor of 3.5 of the statistical accuracy compared with our previous result [J. Gu\'ena et al., Phys. Rev. Lett. 90, 143001 (2003)]. Decisive improvements to the set-up include an increased repetition rate, better extinction of the probe beam at the end of the probe pulse and, for the first time to our knowledge, the following: a polarization-tilt magnifier, quasi-suppression of beam reflections at the cell windows, and a Cs cell with electrically conductive windows. We also present real-time tests of systematic effects, consistency checks on the data, as well as a 1% accurate measurement of the electric field seen by the atoms, from atomic signals. PV measurements performed in seven different vapor cells agree within the statistical error. Our present result is compatible with the more precise Boulder result within our present relative statistical accuracy of 2.6%, corresponding to a 2 \times 10^{-13} atomic-unit uncertainty in E_1^{pv}. Theoretical motivations for further measurements are emphasized and we give a brief overview of a recent proposal that would allow the uncertainty to be reduced to the 0.1% level by creating conditions where asymmetry amplification is much greater.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Measurement of the parity violating 6S-7S transition amplitude in cesium achieved within 2 \times 10^{-13} atomic-unit accuracy by stimulated-emission detection does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Measurement of the parity violating 6S-7S transition amplitude in cesium achieved within 2 \times 10^{-13} atomic-unit accuracy by stimulated-emission detection, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Measurement of the parity violating 6S-7S transition amplitude in cesium achieved within 2 \times 10^{-13} atomic-unit accuracy by stimulated-emission detection will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-146920

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.