Physics
Scientific paper
Jan 1974
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=1974p%26ss...22...19r&link_type=abstract
Planetary and Space Science, Volume 22, Issue 1, p. 19-24.
Physics
1
Scientific paper
On 16 March 1973, the York U./U.S.U. chemiluminescent nitric oxide instrument was flown successfully from Hollomon Air Force Base, New Mexico, 32° 50.1' N lat. The instrument was operated between 17:40 and 22:05UT. Most of the measurements were carried out during three ascent, float and descent cycles between 17.4 and 22.9 km. Within the uncertainty of the measurements no differences were seen among results obtained during ascent, float and descent mode, which indicated that there were no major sampling problems resulting from contamination of the atmosphere. The NO mixing ratio was found to be 0.1 ppb v/v with an accuracy of 60 per cent. No change was observed within this accuracy over the small altitude range investigated.
Ashenfelter T. E.
Bates L.
Howlett Cullan
Levaux H.
Megill Lawrence R.
No associations
LandOfFree
Measurement of nitric oxide in the stratosphere between 17.4 and 22.9 km does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Measurement of nitric oxide in the stratosphere between 17.4 and 22.9 km, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Measurement of nitric oxide in the stratosphere between 17.4 and 22.9 km will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1840729