A Negative Ion Time Projection Chamber was used to measure the field
dependence of lateral and longitudinal diffusion for CS$_2$ anions drifting in
mixtures of CS$_2$ and Ar at 40 Torr. Ion drift velocities and limits on the
capture distance for electrons as a function of field and gas mixture are also
reported.
Martoff Jeff C.
Ohnuki Tohru
Snowden-Ifft Daniel P.
No associations
LandOfFree
Measurement of Carbon Disulfide Anion Diffusion in a TPC does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Measurement of Carbon Disulfide Anion Diffusion in a TPC, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Measurement of Carbon Disulfide Anion Diffusion in a TPC will most certainly appreciate the feedback.