Measurement and uncertainties of energy loss in silicon over a wide Z1 range using time of flight detector telescopes

Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

The energy loss of projectiles with Z1 in the range 3-26 has been experimentally measured in the 0.1-0.7 MeV per nucleon energy range in the same Si stopping foil of 105.5 /μgcm-2 thickness using a time of flight-energy (ToF-E) elastic recoil detection analysis (ERDA) setup. A detailed study of the experimental uncertainties for ToF-E and ToF-ToF-E configuration has been made. For ERDA configurations where the energy calibration is taken against the edge positions small uncertainties in the angle at which recoils are detected can introduce significant absolute uncertainty. The relative uncertainty contribution is dominated by the energy calibration of the Si E detector for the ToF-E configuration and the position of the second ToF detector in ToF-ToF-E measurements. The much smaller calibration uncertainty for ToF-ToF-E configuration implies this technique is superior to ToF-E measurements with Si E detectors. At low energies the effect of charge changing in the time detector foils can become important. It was found that empirical stopping numbers which include the effect of effective-charge were more closely clustered about a trend line when plotted against the Bohr /ξ parameter than the corresponding Bethe parameter. Study of the deviations from the trend line showed evidence of a shell dependant effect that exceeded the anticipated maximum relative uncertainties.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Measurement and uncertainties of energy loss in silicon over a wide Z1 range using time of flight detector telescopes does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Measurement and uncertainties of energy loss in silicon over a wide Z1 range using time of flight detector telescopes, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Measurement and uncertainties of energy loss in silicon over a wide Z1 range using time of flight detector telescopes will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1861726

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.