Lunar Neutral Exosphere Properties from Pickup Ion Analysis

Physics – Plasma Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

[5405] Planetary Sciences: Solid Surface Planets / Atmospheres, [6250] Planetary Sciences: Solar System Objects / Moon, [7800] Space Plasma Physics

Scientific paper

Composition and structure of neutral constituents in the lunar exosphere can be determined through measurements of phase space distributions of pickup ions borne from the exosphere [1]. An essential point made in an early study [1] and inferred by recent pickup ion measurements [2, 3] is that much lower neutral exosphere densities can be derived from ion mass spectrometer measurements of pickup ions than can be determined by conventional neutral mass spectrometers or remote sensing instruments. One approach for deriving properties of neutral exospheric source gasses is to first compare observed ion spectra with pickup ion model phase space distributions. Neutral exosphere properties are then inferred by adjusting exosphere model parameters to obtain the best fit between the resulting model pickup ion distributions and the observed ion spectra. Adopting this path, we obtain ion distributions from a new general pickup ion model, an extension of a simpler analytic description obtained from the Vlasov equation with an ion source [4]. In turn, the ion source is formed from a three-dimensional exospheric density distribution, which can range from the classical Chamberlain type distribution to one with variable exobase temperatures and nonthermal constituents as well as those empirically derived. The initial stage of this approach uses the Moon’s known neutral He and Na exospheres to derive He+ and Na+ pickup ion exospheres, including their phase space distributions, densities and fluxes. The neutral exospheres used are those based on existing models and remote sensing studies. As mentioned, future ion measurements can be used to constrain the pickup ion model and subsequently improve the neutral exosphere descriptions. The pickup ion model is also used to estimate the exosphere sources of recently observed pickup ions on KAGUYA [3]. Future missions carrying ion spectrometers (e.g., ARTEMIS) will be able to study the lunar neutral exosphere with great sensitivity, yielding the necessary ion velocity spectra needed to further analysis of parent neutral exosphere properties. [1] R. E. Hartle and G. E. Thomas, J. Geophys. Res., 79, 1519, 1974. [2] U. Mall et al., J. Geophys. Res., 25, 3799, 1998. [3] S. Yokota et al., Geophys. Res. Lett. 36, L11201, doi:10.1029/2009GL038185, 2009. [4] R. E. Hartle and E. C. Sittler, J. Geophys. Res., 112, A07104, doi:10.1029/2006JA012157, 2007.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Lunar Neutral Exosphere Properties from Pickup Ion Analysis does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Lunar Neutral Exosphere Properties from Pickup Ion Analysis, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Lunar Neutral Exosphere Properties from Pickup Ion Analysis will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1769721

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.