Low-frequency method for magnetothermopower and Nernst effect measurements on single crystal samples at low temperatures and high magnetic fields

Physics – Instrumentation and Detectors

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

11 pages, 6 figures, 15 references

Scientific paper

10.1063/1.1353192

We describe an AC method for the measurement of the longitudinal (Sxx) and transverse (Sxy, i.e. Nernst) thermopower of mm-size single crystal samples at low temperatures (T<1 K) and high magnetic fields (B>30 T). A low-frequency (33 mHz) heating method is used to increase the resolution, and to determine the temperature gradient reliably in high magnetic fields. Samples are mounted between two thermal blocks which are heated by a sinusoidal frequency f0 with a p/2 phase difference. The phase difference between two heater currents gives a temperature gradient at 2f0. The corresponding thermopower and Nernst effect signals are extracted by using a digital signal processing method due. An important component of the method involves a superconducting link, YBa2Cu3O7+d (YBCO), which is mounted in parallel with sample to remove the background magnetothermopower of the lead wires. The method is demonstrated for the quasi two-dimensional organic conductor a-(BEDT-TTF)2KHg(SCN)4, which exhibits a complex, magnetic field dependent ground state above 22.5 T at low temperatures.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Low-frequency method for magnetothermopower and Nernst effect measurements on single crystal samples at low temperatures and high magnetic fields does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Low-frequency method for magnetothermopower and Nernst effect measurements on single crystal samples at low temperatures and high magnetic fields, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Low-frequency method for magnetothermopower and Nernst effect measurements on single crystal samples at low temperatures and high magnetic fields will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-372087

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.