44 pages, 2 figures

Scientific paper

10.1016/j.nima.2007.09.019

In this article we derive longitudinal impedance and wake function for an undulator setup with arbitrary undulator parameter, taking into account a finite transverse size of the electron bunch. Earlier studies considered a line density-distribution of electrons instead. We focus our attention on the long-wavelength asymptote (compared with resonance wavelength), at large distance of the electron bunch from the undulator entrance compared to the overtaking length, and for large vacuum-chamber size compared to the typical transverse size of the field. These restrictions define a parameter region of interest for practical applications. We calculate a closed expression for impedance and wake function that may be evaluated numerically in the most general case. Such expression allows us to derive an analytical solution for a Gaussian transverse and longitudinal bunch shape. Finally, we study the feasibility of current-enhanced SASE schemes (ESASE) recently proposed for LCLS, that fall well-within our approximations. Numerical estimations presented in this paper indicate that impedance-induced energy spread is sufficient to seriously degrade the FEL performance. Our conclusion is in contrast with results in literature, where wake calculations for the LCLS case are given in free-space, as if the presence of the undulator were negligible.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Longitudinal impedance and wake from XFEL undulators. Impact on current-enhanced SASE schemes does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Longitudinal impedance and wake from XFEL undulators. Impact on current-enhanced SASE schemes, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Longitudinal impedance and wake from XFEL undulators. Impact on current-enhanced SASE schemes will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-549573

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.