Physics – Atomic Physics
Scientific paper
2011-09-16
Physics
Atomic Physics
Scientific paper
We present a local measurement of gravity combining Bloch oscillations and atom interferometry. With a falling distance of 0.8 mm, we achieve a sensitivity of 2x10-7 g with an integration time of 300 s. No bias associated with the Bloch oscillations has been measured. A contrast decay with Bloch oscillations has been observed and attributed to the spatial quality of the laser beams. A simple experimental configuration has been adopted where a single retro-reflected laser beam is performing atoms launch, stimulated Raman transitions and Bloch oscillations. The combination of Bloch oscillations and atom interferometry can thus be realized with an apparatus no more complex than a standard atomic gravimeter.
Bidel Yannick
Bresson Alexandre
Cadoret Malo
Charrière Renée
Zahzam Nassim
No associations
LandOfFree
Local gravity measurement with the combination of atom interferometry and Bloch oscillations does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Local gravity measurement with the combination of atom interferometry and Bloch oscillations, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Local gravity measurement with the combination of atom interferometry and Bloch oscillations will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-534929