Iridium optical constants from x-ray transmission measurements over 2 to 12 keV

Physics – Optics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

Precise transmission measurements of free standing iridium foils and of iridium coatings supported on thin polyimide film have been made at the X8 beamline of the National Synchrotron Light Source, at energies from 2 to 12 keV. These measurements were conducted to provide iridium optical constants in support of NASA's Advanced X-ray Astrophysics Facility (AXAF). Transmission data were collected at small energy increments across iridium M and L absorption edges to study detailed edge structures. From these data, the imaginary components of the index of refraction were computed. The data also allows computation of the real parts, using the Kramers-Kronig dispersion integral. Preliminary results indicate a measurement accuracy of better than one percent for transmission. Absorption coefficients deviate by varying amounts from values predicted from Henke data table, which is consistent with the accuracy claimed for those table.s Nonuniform thickness in our iridium foils may be a source of errors in our analysis and improved foils are being sought. Additional measurements will also be needed with foils of different thickness to account and correct for possible effects of sample thickness on the determination of absorption edge fine structure. To our knowledge, transmission measurements of this degree of accuracy and precision have not been previously reported in the literature for iridium in the 2- 12 keV energy range.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Iridium optical constants from x-ray transmission measurements over 2 to 12 keV does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Iridium optical constants from x-ray transmission measurements over 2 to 12 keV, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Iridium optical constants from x-ray transmission measurements over 2 to 12 keV will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1384378

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.