Physics
Scientific paper
Mar 2004
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2004paun.conf..211f&link_type=abstract
PARTICLES AND THE UNIVERSE. Proceedings of the Eighteenth Lake Louise Winter Institute. Held 16-22 February 2003 in Lake Louise,
Physics
Scientific paper
The in-situ intercalibration of the PbWO4 crystals of the CMS electromagnetic calorimeter will be performed using three techniques: An energy-flow method will be used at startup to intercalibrate to a precision of around 2% within about three hours. The energy/momentum measurement of isolated electrons from W → eν events will then be used to obtain the design goal precision of 0.5% within about two months. Global intercalibration of different regions of the calorimeter and the determination of the absolute energy scale will be performed using energetic electrons from Z→ e+e- events.
No associations
LandOfFree
In-Situ Calibration of the CMS Electromagnetic Calorimeter does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with In-Situ Calibration of the CMS Electromagnetic Calorimeter, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and In-Situ Calibration of the CMS Electromagnetic Calorimeter will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1028677