Physics – Optics
Scientific paper
May 1994
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=1994aas...184.2701l&link_type=abstract
American Astronomical Society, 184th AAS Meeting, #27.01; Bulletin of the American Astronomical Society, Vol. 26, p.897
Physics
Optics
6
Scientific paper
The Guide Star Automatic Measuring MAchine (GAMMA) is a laser-illuminated multi-channel scanning microdensitometer, modularly built upon the substrate of the modified PDS used in earlier ST ScI work (\it A.J., 99, 2019). A rebuild of the x- and y-servos is based on a HP 5507 laser transducer system with a custom card to implement the PDS ``1/N" functionality. The light source is a spatially filtered 2 mW HeNe laser beam, expanded to 1 mm (FW1/e(2) ), moved with a TeO_2 acousto-optic deflector (AOD), and finally imaged on the plate as a 42 microns Gaussian spot. This size gives low aliasing with the adopted 15 microns sampling. The table moves in x\ at 100 mm/sec, while the AOD steps the laser beam through a small number of channels, typically 5, in the y-direction. The AOD is controlled by a frequency synthesizer operated from a digital signal processor (DSP) which cycles through a channel-to-frequency table, synchronized by pulses from the servo 1/N logic. The DSP also removes y-position errors due to residual servo auto-lock disequilibrium by applying a small frequency correction to the AOD, based on a linear function of the error signal from the y-servo. The light collecting optics consists of a standard microscope, an exit slit, an integrating sphere to make the response insensitive to the channel number, and a photomultiplier. Pixel times are about 25-50 mu sec, and the data conversion is done with a floating point ADC. A separate photodiode to monitor the laser flicker is also provided for photometric normalization. A dedicated Vax-Station with IEEE-488 and CAMAC interfaces controls the GAMMA. Separate programs operate each subsystem (servo, data collection, laser monitoring, AOD, console), and communicate with each other via shared memory and common event flags. This matching of the s/w and h/w architectures results in easily maintainable code. Final integration testing is now in progress, and routine operation with 5-10 hour scan times is anticipated.
Evzerov Anatoly
Greene Gretchen R.
Laidler Victoria G.
Lasker Barry M.
Ray Knute
No associations
LandOfFree
GAMMA -- A New High-speed Microdensitometer Built on a PDS Substrate does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with GAMMA -- A New High-speed Microdensitometer Built on a PDS Substrate, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and GAMMA -- A New High-speed Microdensitometer Built on a PDS Substrate will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-882144