Physics – Optics
Scientific paper
Jul 2008
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2008spie.7015e..80m&link_type=abstract
Adaptive Optics Systems. Edited by Hubin, Norbert; Max, Claire E.; Wizinowich, Peter L. Proceedings of the SPIE, Volume 7015
Physics
Optics
Scientific paper
Most computers in the past have been equipped with floating point processing capabilities, allowing an easy and brute-force solution for the machine computation errors, not requiring any specific tailoring of the computation in nearly hundred percent of situations. However, the computation needed for the adaptive optics real-time control in 30-50 meter telescopes is big enough to cause trouble to conventional von-Neumann processors, even if Moore's Law is valid for the next years. Field Programmable Gate Array (FPGAs) have been proposed as a viable alternative to cope with such computation needs[1,2], but--at least today's chips--will require fixed-point arithmetic to be used instead. It is then important to evaluate up to what point the accuracy and stability of the control system will be affected by this limitation. This paper presents the simulation and laboratory results of the comparison between both arithmetics, specifically evaluated in an adaptive optics system. The real-time controller has been modeled as black box having as input the wavefront sensor camera digital output data, providing a digital output to the actuators of the deformable mirror, and with the task of internally computing all outputs from the inputs. MATLAB fixed-point library has been used to evaluate the effect of different precision lengths (5-10 fractional bits) in the computation of the Shack-Hartmann subaperture centroid, in comparison with the reference 64-bit floating-point arithmetic and with the noise floor of the real system, concluding that the effect of the limited precision can be overcome by adequately selecting the number of fractional bits used in the representation, and tailoring that number with the needs at every step of the algorithm.
Garcia-Talavera Marcos R.
Martín-Hernando Yolanda
Rodríguez-Ramos Luis-Fernando
No associations
LandOfFree
Fixed-point vs. floating-point arithmetic comparison for adaptive optics real-time control computation does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Fixed-point vs. floating-point arithmetic comparison for adaptive optics real-time control computation, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Fixed-point vs. floating-point arithmetic comparison for adaptive optics real-time control computation will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-791686