Physics – Nuclear Physics – Nuclear Experiment
Scientific paper
1998-07-29
Nucl.Instrum.Meth. A430 (1999) 507-511
Physics
Nuclear Physics
Nuclear Experiment
3 pages, 1 table, 3 figures, submitted to NIM A ; 4 pages, 1 table, 5 figures, added discussion and figures
Scientific paper
10.1016/S0168-9002(99)00225-9
A method for plasma delay and pulse-height defect corrections for Si surface barrier detectors (SBD) is presented. Based on known empirical formulae, simple approximations involving the measured time-of-flight (TOF) and energy of the ions were found and a mass reconstruction procedure was developed. The procedure was applied for obtaining the fission fragment mass and angular distributions from the $^{64}$ Ni+$^{197}$Au reaction at 418 MeV and 383 MeV incident energy using an array of eight SBDs.
McGrath Robert L.
Velkovska Julia
No associations
LandOfFree
Fission fragment mass reconstruction from Si surface barrier detector measurement does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Fission fragment mass reconstruction from Si surface barrier detector measurement, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Fission fragment mass reconstruction from Si surface barrier detector measurement will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-112554