First test of a cryogenic scintillation module with a CaWO4 scintillator and a low-temperature photomultiplier down to 6 K

Physics – Nuclear Physics – Nuclear Experiment

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

10.1016/j.nima.2010.05.008

Future cryogenic experiments searching for rare events require reliable, efficient and robust techniques for the detection of photons at temperatures well below that to which low-temperature photomultipliers (PMT) were characterised. Motivated by this we investigated the feasibility of a low-temperature PMT for the detection of scintillation from crystalline scintillators at T = 6 K. The scintillation module was composed of a CaWO4 scintillator and a low-temperature PMT D745B from ET Enterprises. The PMT responsivity was studied at T=290, 77 and 6 K using gamma-quanta from 241Am (60 keV) and 57Co (122 and 136 keV) sources. We have shown that the low-temperature PMT retains its single photon counting ability even at cryogenic temperatures. At T = 6 K, the response of the PMT decreases to 51 +- 13 % and 27 +- 6 % when assessed in photon counting and pulse height mode, respectively. Due to the light yield increase of the CaWO4 scintillating crystal the overall responsivity of the scintillation modules CaWO4+PMT is 94 +- 15 % (photon counting) and 48 +- 8 % (pulse height) when cooling to T = 6 K. The dark count rate was found to be 20 s-1. The energy resolution of the module remains similar to that measured at room temperature using either detection mode. It is concluded that commercially available low-temperature PMT are well suited for detection of scintillation light at cryogenic temperatures.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

First test of a cryogenic scintillation module with a CaWO4 scintillator and a low-temperature photomultiplier down to 6 K does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with First test of a cryogenic scintillation module with a CaWO4 scintillator and a low-temperature photomultiplier down to 6 K, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and First test of a cryogenic scintillation module with a CaWO4 scintillator and a low-temperature photomultiplier down to 6 K will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-707028

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.