The electromagnetic calorimeter of PANDA at the FAIR facility will rely on an operation of lead tungstate (PWO) scintillation crystals at temperatures near -25 deg.C to provide sufficient resolution for photons in the energy range from 8 GeV down to 10 MeV. Radiation hardness of PWO crystals was studied at the IHEP (Protvino) irradiation facility in the temperature range from room temperature down to -25 deg.C. These studies have indicated a significantly different behaviour in the time evolution of the damaging processes well below room temperature. Different signal loss levels at the same dose rate, but at different temperatures were observed. The effect of a deep suppression of the crystal recovery process at temperatures below 0 deg.C has been seen.
Burachas S. F.
Davidenko A. M.
Derevschikov A. A.
Goncharenko Yu. M.
Ippolitov M. S.
No associations
LandOfFree
First study of radiation hardness of lead tungstate crystals at low temperatures does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with First study of radiation hardness of lead tungstate crystals at low temperatures, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and First study of radiation hardness of lead tungstate crystals at low temperatures will most certainly appreciate the feedback.